This is the revolutionary product we have been waiting for in the wind power community. A quality made grid tie that meets all of those certifications your power utility will be sure to ask about. Islanding protection VAC, FAC in accordance with UL 1741, IEEE929, G83/1, G59, AS4777 . Powerful 2 KW system with 30 to 750 volt input range. Paired up with the proper wind power products this is the beginning of significant progress in wind power . Controller with dump load is used to rectify frequency-variable output voltage of the wind turbine generator to DC voltage before feeding into the grid tie inverter. It is not only protecting against overvoltage for the wind turbine system, but providing the replaced load when the grid is down. There are three different voltage protecting points you can set in the controller.
| Model |
2k
|
|
|
|
| Energy Source |
Wind
|
PV
|
|
|
|
|
|
|
| AC Nominal Power (kW) |
2
|
|
|
|
| DC Input Voltage Range (VDC) |
30 - 750
|
100-600
|
|
|
|
| Operating Range Utility Voltage (VAC) |
190 - 260 (adjustable)
|
|
| Operating Range Utility Frequency (Hz) |
47 - 52 or 57 - 62 (ajustable)
|
| Total Harmonic Distortion (THD) |
THDAC< 4 %
|
| Power Factor |
>0.99
|
| Efficiency |
>94%
|
|
|
|
| Utility Monitoring |
Islanding protection VAC, FAC in accordance with UL 1741, IEEE929, G83/1, G59, AS4777
|
| Communication Interfaces |
RS485
|
| Operation Surroundings Temperature |
-25℃ ~ +60℃
|
| Operation Surroundings Humidity |
0 ~ 95%
|
| Ingress Protection |
IP65
|
| EMC |
EN50081,part1 EN50082,part1
|
| Grid Interference |
EN61000-3-2
|
| Safety |
Short circuit protection, islanding protection, over heat protection, over load protection
|
Manufacturer: N/A
SKU: N/A